<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15686</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: calculated balance weight offset too large
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_VLF</Text></ListItem>
<ListItem><Text>Trendsetter</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Confirm balance weight is positioned under leading edge clamps.
NOTE:  This error is obsolete in VLF trendsetter version 1.40 and newer.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
This is not an operator serviceable error.  Press resume or reset the
machine to continue production.  Call CreoScitex response center.
</text></DescriptionText>
</OperatorAction>
<Cause>
The balance weight offset is greater than 1 detent spacing.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:19 2008 PST
</Updated>
<Links>
</Links>
</Error>
